10. Three-dimensional buildings may require more than a planar push.
•For building with strong asymmetry in plan, or with numerous non-orthogonal elements, a planar (two dimensional) push-over analysis may not suffice. 
•For such cases a 3D model of the building must be constructed and subjected to
push-over analysis. 
•Three dimensional buildings
may be pushed in the principal directions independently, or
pushed simultaneously in
orthogonal directions.